Danfoss Hansen FD-83 coupling is designed for fluid transfer and electronics cooling applications where full flow, fluid compatibility and safety are essential.
--- Danfoss Hansen FD83 series dry break couplings are high-performance, leak-tight quick connectors engineered for liquid cooling systems in data centers. --- Featuring an interlock safety mechanism, the coupling can only open the internal flow path when the male and female halves are fully engaged. --- Before disconnection, the valve must be fully closed to prevent coolant spillage, which effectively protects equipment and reduces maintenance risks.
Danfoss Hansen FD83 series dry break coupling constructed from stainless steel with robust EPDM sealing rings, delivers excellent corrosion resistance and long service life under continuous cooling fluid circulation.
The full-flow internal design minimizes pressure drop and supports stable flow of ethylene glycol and other cooling media.
Equipped with barbed hose ports for simple hose assembly, these couplings come with protective caps to guard the sealing surface against dust and scratches during storage and transportation.
Typically deployed in cold plate liquid cooling loops for servers, FD83 quick disconnects enable fast, clean connection and disconnection for cabinet maintenance, upgrades or replacement.
Features and benefits
Dual interlock safety feature eliminates accidental opening of coupling when disconnected with the use of a patented locking pin design and lever handle.
Design provides reliable performance and no spillage during maintenance or serviceStandard seal material: EPDM-P (Peroxide cured).
Standard body material: 303 stainless steel.
Full flow coupling.
Identical coupling halves.
Maintenance and service friendly.
Passivated 303 stainless steel material provides broad fluid compatibility.
Wide range of terminal end options.
Temperature range: 4°C (39°F) to 60°C (140°F)
All EPDM peroxide-cured seals and O-rings used in our products are certified in accordance with IEC 62368-1G.15.2.3 under file MH67791, Volume 1.
No-leak, no-drip designs.
High flow and low pressure drop.
Easy and safe connection and disconnection.
Corrosion-resistant anodized aluminum, stainless steel, or composite plastic options.
100% helium leak tested.
Unlimited configuration options.
No extra clamps or additional components needed.
Technical Datas
Applications
Battery cooling
Converter cooling
Data centers
Electronic component cooling
Electric vehicle and bus
IT thermal management
Processing